Home     Xml Feed    Submit Articles     Editor Login
More4you Article Directory
  RSS Feeds   Add us to favorites
  Make us your home page
You want more tips, training and tutorials... everything you need to make your web site and business a success?

You get that and much more with the More4you Blogletter!

Subscribe today for free!

Email address:*

First name:

* required field

Sponsors
  • Discover How A Measly $1 A Day Can INCREASE Your Online Sale
  • sponsor AudioGenerator.com
  • Cash in on the multi billion dollar domain name industry!
  • sponsor WebSite.ws
  • The Web Host Top Internet Marketers Choose...
  • sponsor WebHostingSecret.com
  • The Pool Pays Today! Paid monthly with zero recruiting!
  • sponsor The.LawnChairMillionaire.com
    Categories
    Advertising
    Advice
    Affiliate Programs
    Auto & Trucks
    Awards
    Blogs
    Book Reviews
    Business
    Careers
    Communication
    Computers
    Copywriting
    CSS
    Dating
    Direct Mail
    Domain Names
    EBooks
    ECommerce
    Education
    Email
    Entertainment
    Environment
    Family
    Finance
    Fitness
    Food & Drink
    Free
    Gadgets & Gizmos
    Gambling
    Gardening
    Government
    Health
    Hobbies
    Home Accessories
    Home Business
    Home Repair
    HTML
    Humor
    Insurance
    Internet
    Investment
    Kids & Teens
    Law
    Link Popularity
    Malware
    Management
    Marketing
    Marriage
    Men`s Issues
    Metaphysical
    MLM
    Motivational
    Movies
    Multimedia
    Music
    Newsletters
    Non-Profit
    Off-Line Promotion
    Online Business
    Online Promotion
    Other
    Outdoors
    Parenting
    Pets & Animals
    Politics
    Press Releases
    Product Reviews
    Psychology
    Publishing
    Real Estate
    Recreation
    Relationships
    Religion & Faith
    RSS
    Sales
    Scams
    Science
    SE Optimization
    SE Positioning
    SE Tactics
    Security
    Self Help
    Sexuality
    Site Security
    Social Issues
    Spam
    Spirituality
    Sports
    Technology
    Traffic Analysis
    Travel
    Viral Marketing
    Web Design
    Web Hosting
    Webmasters
    Weight Loss
    Women`s Issues
    Writing


    Fire Investigation
    Author: David Robinson
    Website: http://innotas.com
    Added: Mon, 26 Nov 2007 19:23:54 -0500
    Category: Science
    Printable version | Email | Bookmark

    The fire in question occurred at a restaurant. When the fire department arrived, heavy smoke was observed but no flaming could be seen. Firefighters did not locate the source of the smoke until the fire - emanating from the floor/ceiling which separated the area from a storage room below - broke through the kitchen floor. Both local fire department investigators and a private fire cause and origin investigator [hired by the party who ultimately became the plaintiff in the case] investigated the fire. Their work determined that the fire started in the void space between the basement storeroom ceiling and kitchen floor.

    In the process of conducting that investigation, a fluorescent light fixture which had been mounted to the storeroom ceiling was located in the fire debris. As part of recognized fire investigation processes, three separate investigators concluded by a process of elimination that the fire started at the fixture location. Contrary to Mr. Burnette’s comments, the investigators are reported to have ruled out associated building wiring as a fire cause to their satisfaction based on the evidence available. We need DP on this one!

    Like most fluorescent fixtures, the damaged but intact fixture which was recovered contained a ballast. A ballast is a transformer which converts line voltage to higher voltages capable of powering a fluorescent tube.

    The private cause and origin investigator disassembled the fixture and determined its manufacturer. The ballast was determined to be manufactured by Magnetek, an eventual defendant in the case.

    An additional expert whose qualifications included a Ph.D. in physics and 20 years experience in studying fires and explosions also evaluated the evidence. He observed oxidation patterns on the fixture and discoloration of the ballast's heating coils. These observations indicated that, prior to the structural fire which occurred, the ballast had shorted, causing internal overheating.

    Technical Issues:

    This ballast design in this case contained a device called a thermal protector. The thermal protector is a combination temperature sensor and switch with a thermal reset feature. When functioning normally, the thermal protector would de-energize the ballast when it sensed temperatures exceeding 111oC [232o F]. This would cause the light to go off signaling to building occupants that something was amiss with the light installation. When temperatures at the thermal protector fall below 111oC [232o F], the thermal protector restores power to the ballast and the light will once again illuminate.

    In the fire at issue, examination of the [incident] thermal protector in the ballast demonstrated that it continued to function even after the fire had occurred, effectively eliminating a temperature excursion based on a thermal protector malfunction before the fire. The Court of Appeals’ opinion is silent in terms of testimony as to what management or staff knew about the ballast. However, if it had been cycling, that would have been a sign that thermal failure was taking place.

    As part of the investigative process, tests were conducted by plaintiff's experts who faulted exemplars of the ballast at issue and observed the results. In this case, the ballast reached temperatures of 340o F cycled off and then cycled on once again once cooling

    occurred. That testing demonstrated that routine operation of the ballast would occur at temperatures in the range of 149oC [300 o F] as it cycled on and off which is below accepted short term wood ignition temperatures but significantly higher than safe wood exposure temperatures in the range of 90oC [XXX o F] as allowed in our building and mechanical codes and common UL and ANSI standards. at . It is especially critical to consider that The Court of Appeals wrote in its opinion that it believed - based on the evidence provided to that court – that wood ignition occured in all cases at temperatures greater than or equal to 204 o C [400o F].

    The plaintiff’s expert expressed the opinion that ballast operating temperatures observed as described above - were lower than ignition temperatures normally accepted for wood adjacent to the ballast. However, the same expert testified in deposition and sought to testify in the trial court that the magnitude of this overheating while below commonly accepted temperatures for the ignition of wood, was sufficient to cause the ignition which occurred because the wood had been subjected to these elevated temperatures for extended periods of time. He characterized that exposure as causing what the court – based on the limited information provided to it - misguidedly referred to in its writings as “pyrolysis”. Accordingly, the plaintiff’ s expert provided an opinion that a short circuit in the ballast created moderate but extended overheating which eventually caused ignition. It was this theory that the Federal Appeals Court referred to as a "pyrolysis theory." That was the opinion upon which this case rose and fell.

    The defendant on the other hand claimed that such a “pyrolysis theory” could not be relied on to explain the start of the fire. In its writings, the courts characterized the proffered theory as suggesting " that ……wood can catch fire at temperatures below 400o F if it is exposed to such temperatures over a long period of time." The court’s writings also indicate that it believed – based on the evidence presented - that temperatures in excess of 204 o C [400o F] were in all cases necessary to ignite wood. This is simply not true. One needs only to look at the 70+ year old table presented above to see that such a threshold number was inaccurate.

    However, the trial court granted the Motions to exclude the plaintiff’s expert’s opinions and entered a Summary Judgment – a process that provided a finding for the defendant.



    View all David Robinson's articles


    About the Author:
    Innotas, Inc. at http://www.innotas.com is a leading Enterprise class Project and Portfolio Management company. Their award-winning projects were recently placed in the Visionary Quadrant on Gartner's well-known analyst reports as well. Find out more about their solutions today at http://innotas.com/solutions/index.html

    More Science articles


    :- Articles Search

      
    Search our article database!

    :- Recent Articles
    Cost Free Jobs, Job Search, Job Hunting and Recruitment Platform
    Backup Data for Maximum Business Uptime
    Experience Immersive Gaming Experience with Authentic PS3 Controller
    Software Application Development—Software Reliability
    Disaster Restoration Solutions
    Poker is just not a absolutely free online game
    Look Awesome with Fine Handcrafted Jewelry!
    Renovation And Restoration - Lead Your Vision Into Reality
    Cash Loans Calgary: Immediate Financial Solution
    More about Panama Hats
    Lourens Haasbroek’s Step By Step Plan to a Guaranteed Income Online
    Windows Address Book Repair software released
    Decorate your living space with American Drew Furniture
    How to Select a Good Recruitment Agency In Mongolia to help you find candidates
    Tips To Plan An Amazing Surprise Party For Your Mother
    Property-In- Dehradun- Residential-commercial-industrial-Properties -plots-Real Estate -House-Properties In Dehradun
    Earning bucks away of Runescape
    The Safest Way to Remove Squirrel and Raccoons
    Mountain bike frames - Cheap bike frames - Road bike frames
    Choosing The Best Online Casino Made Easy

    :- Top Resources


    Copyright 2000- More4you Article Directory. All Rights Reserved.


    Powered by ArticleDirectoryPro